Dec 04, 2017 The HPE Storage Tape Drivers for Windows can be executed in a graphical user interface mode or silent mode. If /s or /silent command line parameter is supplied, the HPE StoreEver Tape Drivers for Windows installer executes quietly without displaying graphical user interface and honors all command line parameters. In graphical user interface. Such device finally exist CXRT SAS to USB adapter CXRT-USB3. You can find it on Amazon, eBay and couple other places. There are 2 downsides in my opinion. It’s almost 100 times more expensive than cheap SATA to USB, around 700$. And it supports only SAS, not SATA so you may need to carry multiple devices. DELL ENTERPRISE CLASS 4TB 7.2K RPM SAS 3.5' 6Gbps HARD DRIVE W/TRAY FOR PowerEdge R210 II R220 R310 R320 R410 R415 R420 R510 R515 R520 R710 R720 R720XD T110 II T310 T320 T410 T420 T620 T710. 3.9 out of 5 stars. Super Speed SAS (Serial Attached SCSI) to USB 3.0 Adapter: This SAS HDD/SSD reader writer can make the data transmission speeds up to 5 GB/s. Fully compatible with USB 2.0, USB 1.1/1.0 devices. No drivers needed. Plug and Play for already formatted hard drive. CentOS supports drivers for many hardware devices but some newly-released drivers may not be supported. A driver update should only be performed if an unsupported driver prevents the installation from completing. Updating drivers during installation is typically only required to support a particular configuration.

  1. Drivers Cartech Sas Usb Devices Download
  2. Drivers Cartech Sas Usb Devices 3.0
  3. Drivers Cartech Sas Usb Devices Adapters
  4. Drivers Cartech Sas Usb Devices Download
-->

Important

StorSimple 8000 series will reach its end-of-life in December 2022. If you are considering new deployments of StorSimple 8000 series, we recommend that you explore other alternatives such as Azure File Sync or Azure Data Box Online devices for your workloads.

Overview

Your Microsoft Azure StorSimple 8600 is a dual enclosure device and consists of a primary and an EBOD enclosure. This tutorial explains how to unpack, rack-mount, and cable the StorSimple 8600 device hardware before you configure the StorSimple software.

Unpack your StorSimple 8600 device

The following steps provide clear, detailed instructions on how to unpack your StorSimple 8600 storage device. This device is shipped in two boxes, one for the primary enclosure and another for the EBOD enclosure. These two boxes are then placed in a single box.

Prepare to unpack your device

Before you unpack your device, review the following information.

WARNING!

  1. Make sure that you have two people available to manage the weight of the device if you are handling it manually. A fully configured enclosure can weigh up to 32 kg (70 lbs.).
  2. Place the box on a flat, level surface.

Next, complete the following steps to unpack your device.

To unpack your device

  1. Inspect the box and the packaging foam for crushes, cuts, water damage, or any other obvious damage. If the box or packaging is severely damaged, do not open the box. Please contact Microsoft Support to help you assess whether the device is in good working order.

  2. Open the outer box and then take out the two boxes corresponding to primary and EBOD enclosures. You can now unpack the primary and EBOD enclosures. The following figure shows the unpacked view of one of the enclosures.

    Unpacked view of your storage device

    LabelDescription
    1Packing box
    2SAS cables (in accessories and cables tray)
    3Bottom foam
    4Device
    5Top foam
    6Accessory box
  3. After unpacking the two boxes, make sure that you have:

    • 1 primary enclosure (the primary enclosure and EBOD enclosure are in two separate boxes)

    • 1 EBOD enclosure

    • 4 power cords, 2 in each box

    • 2 SAS cables (to connect the primary enclosure to EBOD enclosure)

    • 1 crossover Ethernet cable

    • 2 serial console cables

    • 1 serial-USB converter for serial access

    • 4 QSFP-to-SFP+ adapters for use with 10 GbE network interfaces

    • 2 rack mount kits (4 side rails with mounting hardware, 2 each for the primary enclosure and EBOD enclosure), 1 in each box

    • Getting started documentation

      If you did not receive any of the items listed above, contact Microsoft Support.

The next step is to rack-mount your device.

Rack-mount your StorSimple 8600 device

Follow the next steps to install your StorSimple 8600 storage device in a standard 19-inch rack with front and rear posts. This device comes with two enclosures: a primary enclosure and an EBOD enclosure. Both of these need to be rack-mounted.

The installation consists of multiple steps, each of which is discussed in the following procedures.

Important

StorSimple devices must be rack-mounted for proper operation.

Site preparation

The enclosures must be installed in a standard 19-inch rack that has both front and rear posts. Use the following procedure to prepare for rack installation.

To prepare the site for rack installation

  1. Make sure that the primary and EBOD enclosures are resting safely on a flat, stable, and level work surface (or similar).
  2. Verify that the site where you intend to set up has standard AC power from an independent source or a rack Power Distribution Unit (PDU) with an uninterruptible power supply (UPS).
  3. Make sure that one 4U (2 X 2U) slot is available on the rack in which you intend to mount the enclosures.

WARNING!

Make sure that you have two people available to manage the weight if you are handling the device setup manually. A fully configured enclosure can weigh up to 32 kg (70 lbs.).

Rack prerequisites

The enclosures are designed for installation in a standard 19-inch rack cabinet with:

  • Minimum depth of 27.84 inches from rack post to post
  • Maximum weight of 32 kg for the device
  • Maximum back pressure of 5 Pascal (0.5 mm water gauge)

Rack-mounting rail kit

A set of mounting rails will be provided for use with the 19-inch rack cabinet. The rails have been tested to handle the maximum enclosure weight. These rails will also allow installation of multiple enclosures without loss of space within the rack. Install the EBOD enclosure first.

Drivers Cartech Sas USB Devices

To install the EBOD enclosure on the rails

  1. Perform this step only if inner rails are not installed on your device. Typically, the inner rails are installed at the factory. If rails are not installed, then install the left-rail and right-rail slides to the sides of the enclosure chassis. They attach using six metric screws on each side. To help with orientation, the rail slides are marked LH – Front and RH – Front, and the end that is affixed towards the rear of the enclosure has a tapered end.

    Attaching rail slides to the sides of the enclosure

    LabelDescription
    1M 3x4 button-head screws
    2Chassis slides
  2. Attach the left rail and right rail assemblies to the rack cabinet vertical members. The brackets are marked LH, RH, and This side up to guide you through correct orientation.

  3. Locate the rail pins at the front and rear of the rail assembly. Extend the rail to fit between the rack posts and insert the pins into the front and rear-rack post vertical member holes. Be sure that the rail assembly is level.

  4. Secure the rail assembly to the rack vertical members by using two of the metric screws provided. Use one screw on the front and one on the rear.

  5. Repeat these steps for the other rail assembly.

    Attaching rail assemblies to the rack

    LabelDescription
    1Clamping screw
    2Square-hole front rack post screw
    3Left front rail location pins
    4Clamping screw
    5Left rear rail location pins

Mounting the EBOD enclosure in the rack

Using the rack rails that were just installed, perform the following steps to mount the EBOD enclosure in the rack.

To mount the EBOD enclosure

  1. With an assistant, lift the enclosure and align it with the rack rails.

  2. Carefully insert the enclosure into the rails, and then push it completely into the rack cabinet.

    Mounting the enclosure in the rack

  3. Remove the left and right front flange caps by pulling the caps free. The flange caps simply snap onto the flanges.

  4. Secure the enclosure into the rack by installing one provided Phillips-head screw through each flange, left and right.

  5. Install the flange caps by pressing them into position and snapping them into place.

    Installing the flange caps

    LabelDescription
    1Enclosure fastening screw

Mounting the primary enclosure in the rack

After you have finished mounting the EBOD enclosure, you will need to mount the primary enclosure following the same steps.

Note

  • It is possible to have a few empty slots in the rack between the primary enclosure and the EBOD enclosure.
  • Use the provided 2m SAS cable to connect the primary enclosure to the EBOD enclosure.
  • There are no constraints on the relative placement of the head unit to the EBOD unit. Therefore, the primary enclosure can be placed in the top slot and the EBOD enclosure below β€” or vice versa.

The next step is to cable your device for power, network, and serial access.

Cable your StorSimple 8600 device

The following procedures explain how to cable your StorSimple 8600 device for power, network, and serial connections.

Prerequisites

Before you begin to cable your device, you will need:

  • Your primary enclosure and the EBOD enclosure, completely unpacked
  • 4 power cables (2 each for the primary and the EBOD enclosure) that came with your device
  • 2 SAS cables supplied with the device to connect the EBOD enclosure to the primary enclosure
  • Access to 2 Power Distribution Units (PDUs) (recommended)
  • Network cables
  • Provided serial cables
  • Serial-USB converter with the appropriate driver installed on your PC (if needed)
  • Provided 4 QSFP-to-SFP+ adapters for use with 10 GbE network interfaces

SAS and Power cabling

Your device has both a primary enclosure and an EBOD enclosure. This requires the units to be cabled together for Serial Attached SCSI (SAS) connectivity and power.

When setting up this device for the first time, perform the steps for SAS cabling first and then complete the steps for power cabling.

To attach the SAS cables

Drivers Cartech Sas Usb Devices Download

  1. Identify the primary and the EBOD enclosures. The two enclosures can be identified by looking at their respective back planes. See the following image for guidance.

    Back view of primary and EBOD enclosures

    LabelDescription
    1Primary enclosure
    2EBOD enclosure
  2. Locate the serial numbers on the primary and the EBOD enclosures. The serial number sticker is affixed to the back ear of each enclosure. The serial numbers must be identical on both enclosures. Contact Microsoft Support immediately if the serial numbers do not match. See the following illustration to locate the serial numbers.

    Location of serial number sticker

    LabelDescription
    1Ear of the enclosure
  3. Use the provided SAS cables to connect the EBOD enclosure to the primary enclosure as follows:

    1. Identify the four SAS ports on the primary enclosure and the EBOD enclosure. The SAS ports are labeled as EBOD on the primary enclosure and correspond to port A on the EBOD enclosure, as shown in the SAS cabling illustration, below.

    2. Use the provided SAS cables to connect the EBOD port to port A.

    3. The EBOD port on controller 0 should be connected to the port A on EBOD controller 0. The EBOD port on controller 1 should be connected to the port A on EBOD controller 1. See the following illustration for guidance.

      SAS cabling

      LabelDescription
      APrimary enclosure
      BEBOD enclosure
      1Controller 0
      2Controller 1
      3EBOD Controller 0
      4EBOD Controller 1
      5, 6SAS ports on primary enclosure (labeled EBOD)
      7, 8SAS ports on EBOD enclosure (Port A)

To cable your device for power

Note

Both enclosures on your StorSimple device include redundant PCMs. For each enclosure, the PCMs must be installed and connected to different power sources to ensure high availability.

  1. Make sure that the power switches on all the PCMs are in the OFF position.

  2. On the primary enclosure, connect the power cords to both PCMs. The power cords are identified in red in the power cabling diagram, below.

  3. Make sure that the two PCMs on the primary enclosure use separate power sources.

  4. Attach the power cords to the power on the rack distribution units as shown in the power cabling diagram.

  5. Repeat steps 2 through 4 for the EBOD enclosure.

  6. Turn on the EBOD enclosure by flipping the power switch on each PCM to the ON position.

  7. Verify that the EBOD enclosure is turned on by checking that the green LEDs on the back of the EBOD controller are turned ON.

  8. Turn on the primary enclosure by flipping each PCM switch to the ON position.

  9. Verify that the system is on by ensuring the device controller LEDs have turned ON.

  10. Make sure that the connection between the EBOD controller and the device controller is active by verifying that the four LEDs next to the SAS port on the EBOD controller are green.

    Important

    To ensure high availability for your system, we recommend that you strictly adhere to the power cabling scheme shown in the following diagram.

    Power cabling

    LabelDescription
    1Primary enclosure
    2PCM 0
    3PCM 1
    4Controller 0
    5Controller 1
    6EBOD controller 0
    7EBOD controller 1
    8EBOD enclosure
    9PDUs

Network cabling

Your device is in an active-standby configuration: at any given time, one controller module is active and processing all disk and network operations while the other controller module is on standby. If a controller failure occurs, the standby controller immediately activates and continues all the disk and networking operations.

To support this redundant controller failover, you need to cable your device network as shown in the following steps.

To cable for network connection

Drivers Cartech Sas USB Devices
  1. Your device has six network interfaces on each controller: four 1 Gbps and two 10 Gbps Ethernet ports. Refer to the following illustration to identify the data ports on the backplane of your device.

    Back of your device showing the data ports

    LabelDescription
    0,1,4,51 GbE network interfaces
    2,310 GbE network interfaces
    6Serial ports
  2. See the following diagram for network cabling. (The minimum network configuration is shown by solid blue lines. For high availability and performance, additional configuration required is shown by dotted lines.)

Network cabling for your device

LabelDescription
ALAN with Internet access
BController 0
CPCM 0
DController 1
EPCM 1
FEBOD controller 0
GEBOD controller 1
H,IHosts (for example, file servers)
0-5Network interfaces
6Primary enclosure
7EBOD enclosure

When cabling the device, the minimum configuration requires:

Drivers Cartech Sas Usb Devices 3.0

  • At least two network interfaces connected on each controller with one for cloud access and one for iSCSI. The DATA 0 port is automatically enabled and configured via the serial console of the device. Apart from DATA 0, another data port also needs to be configured through the Azure classic portal. In this case, connect DATA 0 port to the primary LAN (network with Internet access). The other data ports can be connected to SAN/iSCSI LAN (VLAN) segment of the network, depending on the intended role.
  • Identical interfaces on each controller connected to the same network to ensure availability if a controller failover occurs. For instance, if you choose to connect DATA 0 and DATA 3 for one of the controllers, you need to connect the corresponding DATA 0 and DATA 3 on the other controller.

Keep in mind for high availability and performance:

  • When possible, configure a pair of network interface for cloud access (1 GbE) and another pair for iSCSI (10 GbE recommended) on each controller.
  • When possible, connect network interfaces from each controller to two different switches to ensure availability against a switch failure. The figure illustrates the two 10 GbE network interfaces, DATA 2 and DATA 3, from each controller connected to two different switches. For more information, refer to the Network interfaces under the High availability requirements for your StorSimple device.

Note

If using SFP+ transceivers with your 10 GbE network interfaces, use the provided QSFP-SFP+ adapters. For more information, go to Supported hardware for the 10 GbE network interfaces on your StorSimple device.

Serial port cabling

Drivers Cartech Sas Usb Devices Adapters

Perform the following steps to cable your serial port.

Drivers Cartech Sas Usb Devices Download

To cable for serial connection

  1. Your device has a serial port on each controller that is identified by a wrench icon. To locate the serial ports, refer to the illustration that shows the data ports on the back of your device.

  2. Identify the active controller on your device backplane. A blinking blue LED indicates that the controller is active.

  3. Use the provided serial cable (if needed, the USB-serial converter for your laptop), and connect your console or computer (with terminal emulation to the device) to the serial port of the active controller.

  4. Install the serial-USB drivers (shipped with the device) on your computer.

  5. Set up the serial connection as follows:

    • 115,200 baud
    • 8 data bits
    • 1 stop bit
    • No parity
    • Flow control set to None
  6. Verify that the connection is working by pressing Enter on the console. A serial console menu should appear.

Note

Lights-Out Management: When the device is installed in a remote datacenter or in a computer room with limited access, ensure that the serial connections to both controllers are always connected to a serial console switch or similar equipment. This allows out-of-band remote control and support operations in case of network disruption or unexpected failures.

You have completed cabling your device for power, network access, and serial connection.The next step is to configure the software on your device.

Next steps

You are now ready to deploy and configure your on-premises StorSimple device.

Some driver installation packages may require you to disable driver signature enforcement in Windows 8, which will allow unsigned driver packages to be installed on your system.

Note: Before you continue, save any open documents and close all open programs.

To disable driver signature enforcement, complete the following:

  1. Press the Windows key + C.
  2. Click Settings > Change PC Settings.
  3. In the left pane, click General.
  4. In the right pane, under Advanced startup, click Restart now.

When your system finishes restarting, complete the following:

  1. Click Troubleshoot > Advanced options > Startup Settings > Restart.
  2. Press 7.

When your computer restarts, driver signature enforcement will be disabled and you can install your drivers.

Note: When you restart your computer after you install your drivers, driver signature enforcement will be enabled again. This does not prevent your newly installed drivers from working, but does prevent any other unsigned drivers from being installed until driver signature enforcement is disabled.